The eye-catching colors of a fire hydrant are hard to miss, whether you’re walking through a city or driving around a neighborhood. What many don’t realize, however, is that these colors are integral in helping emergency responders identify and assess their available resources when preparing to fight a fire. Fire hydrant colors are distinct to make them stand out and provide information to those who need to inspect or use them. Learn how fire hydrants are classified and what their colors represent.

null

How are fire hydrants classified?

The National Fire Protection Association (NFPA) publishes and updates various codes and standards to help formalize how fire safety system elements are installed, inspected, and used. NFPA 291, Recommended Practice for Water Flow Testing and Marking of Hydrants, is the specific standard that addresses why and how hydrants should be classified and marked. Along with other NFPA codes, NFPA 291 helps promote and unify fire safety standards for commercial and residential settings.

When a new building or structure is built, fire codes require the area’s water supply to meet a specific fire flow. The NFPA defines fire flow as the “flow rate of a water supply, measured at 20 psi residual pressure, that is available for firefighting.” This rating is usually calculated based on the needs of a single building, but it can often include allowances to provide support if a fire spreads to nearby structures.

Factors that additionally influence fire flow include:

  • Area of the building
  • Fire resistance ratings
  • Type of construction
  • Occupancy of the structure
  • Presence of fire sprinklers

Based on this requirement, one large-capacity hydrant or several lower-capacity hydrants may be needed to meet a structure’s fire flow, but they rarely appear in immediate clusters. Public fire hydrants in residential areas are often spaced out every 800 feet, and each hydrant must be within 600 feet of a dwelling. In commercial settings with a higher concentration of people in a smaller area, fire hydrants must be within 400 feet of a building and no more than 500 feet away from other hydrants.

With a structure’s fire flow in mind, the main factor that determines how a fire hydrant is classified is its rated capacity. Measured in either gallons or liters per minute (gpm or L/min), the rated capacity of a hydrant is what determines its classification into one of four categories: AA, A, B, and C. Once a fire hydrant is inspected and tested for capacity, it’s painted in a specific set of colors with optional additions to convey its specifications to first responders.

null

What do the different colors mean?

Generally, NFPA 291 recommends that the barrel of a fire hydrant be painted yellow. Reflective paint is an additional benefit for emergency responders who need to identify available hydrants at night or in low lighting. If an entire fire hydrant is painted red or yellow, it is either a privately owned hydrant or a public hydrant in a jurisdiction that has previously adopted a different set of color guidelines.

When looking at a fire hydrant, the color of its top and side parts relays critical information to firefighters. Sometimes called the bonnet, the top part of a hydrant is painted a specific color to indicate the flow capacity available. The caps on each connection are also painted the same color, so the barrel of the fire hydrant is different from its tops and caps. These are the four colors recommended by the NFPA and what they indicate.

A fire hydrant with a light blue top and caps is categorized as a class AA hydrant. These hydrants offer the highest water flow rate for firefighters, with a minimum flow of 1,500 gpm or 5,700 L/min. Due to the vast amount of water available, these hydrants are the best resources for fighting fires in large properties or multi-story buildings.

A fire hydrant painted with a green top and caps is a class A hydrant. The water flow rate for these hydrants ranges from 1,000 to 1,499 gpm or from 3,800 to 5,699 L/min, meaning they can cover the standard fire flow of most structures.

Orange paint on a fire hydrant identifies it as a class B hydrant. These flow rates range from 500 to 999 gpm or 1,900 to 3,799 L/min, so they’re better suited for residential settings or smaller structures.

A fire hydrant with red paint on its top and caps falls in class C, with a maximum flow rate of 500 gpm or 1,900 L/min. Because these are the weakest of the four classes, class C fire hydrants may need to be used in groups to meet a structure’s fire flow.

While the NFPA standardizes these color schemes, NFPA 291 does include notes for several exceptions to its guidelines. In general, these color codes are recommended for public fire hydrants. The code specifies that private hydrants can be marked at the owner’s discretion in a private area. However, if a private hydrant is located on a public street, the NFPA recommends that it be painted red or another color besides yellow to differentiate it from public hydrants.

Additionally, some jurisdictions or municipalities can choose to adopt a different set of colors for their fire hydrants. Colleges and universities, for example, often use their official school colors to decorate fire hydrants on their campuses. In these instances, local fire departments can find additional markings on the hydrants or receive a guide from the institution’s facilities department on their hydrants’ classifications.

Cities may also opt for specific colors that do not align with the guidelines in NFPA 291. Most commonly, local municipalities will paint the barrel of a fire hydrant with the indicator color instead of the top and caps. Silver and white are widely used as a substitute for yellow as well.

null

Are there other guidelines for fire hydrant markings?

In addition to the recommended color schemes, the NFPA outlines some guidelines for how additional information can be conveyed on a fire hydrant:

  • Temporarily out-of-service fire hydrants should be wrapped, covered, or otherwise marked unusable.
  • Permanently inoperative fire hydrants should be removed.
  • Fire hydrants tested below the threshold of 20 psi should have their rated pressures stenciled in black on their tops.
  • Class AA fire hydrants may have their rated capacities stenciled on the tops to ensure they’re conveyed to first responders.
  • Groupings of fire hydrants may benefit from markings that designate the group-flow capacity.

Regardless of whether you follow the NFPA’s color choices, any fire hydrant must be tested and inspected regularly to ensure it works properly in an emergency. With FSS Technologies, staying on top of your commercial fire safety system is a breeze. Our service technicians can help you prepare for fire inspections, from ensuring your fire hydrants are cleared and marked to checking your building’s interior for common fire safety violations. Additionally, we can assess your building’s interior and exterior systems while referencing NFPA standards for commercial fire protection to attain or maintain your company’s fire code compliance. Contact us today to get started.

Explore Our Other Blogs

how-often-fire-inspection-hero-min

How Often Should You Inspect Your Fire Alarm System?

Everyone dreads the day when fire alarm systems are being tested because they are often loud and annoying. However, the importance of making sure your fire alarms are working properly outweighs the small distraction of lights and noise. Putting off a fire alarm inspection can be both risky and negligent for business owners as it…

Continue reading
2019-05_FSSTechnologies_blogs_advantages-of-having-an-alarm-system_hero-min

Advantages of Having an Alarm System

There are a lot of advantages to having an alarm system. For starters, the National Council for Home Safety and Security says that homes without an alarm system are three times as likely to get burglarized.   3 Benefits of Alarm Systems

Continue reading
wired-vs-wireless-hero_1

Hard-Wired vs Wireless Security Systems

The chicken or the egg. Not asking which came first in this case, just which one you like better. In the world of security systems, which came first between wired and wireless was answered long ago. But the question of which is better remains. Let’s start with a quick overview of how each of these…

Continue reading
Hero-kidde-min

Kidde: Innovations in Fire Safety

Your fire alarm system can protect your family, home, and belongings from fires, gas leaks, and other hazards. FSS Technologies is committed to providing its customers with top-of-the-line fire safety and emergency prevention technology, which is why we are a proud provider of products from Kidde, North America’s most installed fire safety brand. Learn about…

Continue reading
smoke-carbon-monoxide-detector-lifespan-hero-min

What is the Lifespan of Smoke and Carbon Monoxide Detectors?

As with pretty much everything, your smoke alarm eventually expires. Sensors can become less sensitive over time, making them less adept at doing their job: detecting smoke, carbon monoxide, or potential fires. Replacing the equipment in your fire safety system is important both at home and in your business. We have developed a quick guide…

Continue reading
HeroVideoStorage-min

What are the Different Kinds of Security Video Storage?

Security Video Recordings Storage How much storage does a security camera have? It is a seemingly simple question, with a surprisingly complicated answer. Security and surveillance cameras can use a variety of storage types, each with their own advantages and disadvantages. To choose the right security video storage for you, you will need to consider…

Continue reading
8-home-security-tips-Hero-min

8 Home Security Tips

With more than 45 years of experience in the home and business security industry, here are our top eight tips for discouraging intruders and burglars from targeting your home. 1. Create the illusion that someone is at your house. If you are going to be gone for an extended time, leave a light or TV…

Continue reading
Hero-fireclass-min

What Are the 5 Classes of Fires?

While it can be hard to tell the difference at first glance, different types of fires occur based on the materials that fuel them. Just as you wouldn’t try to put out a grease fire with water, specific ways to extinguish each fire class exist and depend on what sustains it. Some atypical classes of…

Continue reading
convential-vs-addressable_fire-alarms-hero

Addressable vs. Conventional Fire Alarms

When determining what type of fire alarm systems are best for your business, it boils down to your choice between a conventional and addressable alarm system. The combination of smoke, heat, and carbon monoxide detectors work together with your control panel to keep your business safe. Additionally, you will need to determine what kind of automatic…

Continue reading
Openpath-Hero

Avigilon Alta: The Industry’s Leader in Commercial Access Control

With the rise in popularity of hybrid workspaces and flexible scheduling, more business owners are turning to access control systems to secure their investments. Not only are access control systems the latest standard for commercial security, but FSS Technologies is a proud partner with Avigilon Alta, the leading access control system manufacturer. Why Avigilon Alta?…

Continue reading
24h emergency
Secure My Space
chat with us