What are Fire Ratings?


Any business owner would be devastated by a fire, and most turn to fire safety systems for preventative and protective solutions. Still, many are unaware that their building's materials can directly influence how a fire impacts their building's structure. In addition to investing in a comprehensive fire safety system, it is critical to consider the fire ratings of your building to ensure your system fits the unique needs of your structure's components. Learn how fire ratings are determined and why they matter for structural fire safety.

What are fire ratings?

A fire rating is a grade given to specific materials based on various factors related to how they respond to fires. Different tests are conducted to determine two types of fire ratings for materials that resist or protect against fires. Fire resistance ratings relate to how a structure's foundational materials would respond in the event of a fire, and fire protection ratings are specific to the protective qualities of elements like fire doors.

How are fire ratings determined?

Ratings were developed to categorize building materials based on how they performed regarding fire protection and prevention. The National Fire Protection Association (NFPA) details fire-resistant building construction requirements, and specific tests help identify a building's overall fire safety needs and risks based on the fire rating of its materials.

To help standardize how fire ratings are determined in the US, the American Society for Testing and Materials (ASTM) recognized two tests that help determine a material's fire rating: the ASTM E84 and the ASTM E119. Similar tests that are on par with these have been developed by the NFPA and Underwriters Laboratories (UL) to assist in creating national and international standards for building safety. These tests are recognized using specific criteria from the International Building Code (IBC) for each test.

Also referred to as the Steiner Tunnel Test, the ASTM E84 measures the fire-resistant characteristics of various building materials. Using a contained testing area with controlled airflow and fire exposure, the test measures how a specific material reacts to an active flame. The two primary measurements from this test that impact a fire rating are how quickly the flame progresses and how much smoke develops.

In addition to those metrics, the ASTM E84 also measures:

  • Time to ignition
  • Flame spread distance over time
  • Maximum flame spread distance
  • Temperature over time
  • Time to maximum temperature
  • Smoke area over time

In contrast, the ASTM E119 is a time-based test with its own criteria that identifies how long a structural component can withstand a fire. Instead of a single material, an entire assembly, such as a wall or column, undergoes a fire-resistance test to see if it can maintain structural integrity while containing a fire and protecting the rest of a building. The results are measured in whole hours, so a rating of "one hour" means a specific structure can withstand a fire for up to an hour.

What are the 3 fire rating classes?

Once an ASTM E84 or similar test is conducted, materials are categorized into one of three classes determined by the IBC based on how quickly a fire would spread and how much smoke would develop. The Flame Spread Index (FSI) is measured on a scale of 0 to 200, and scores are rounded to the nearest multiple of 5. The Smoke Developed Index (SDI) ranges between 0 and 450; values less than 200 are rounded to the nearest multiple of 5, while values over 200 are rounded to the nearest multiple of 50. Considering the FSI and SDI identified in a test, a material is rated as Class A, B, or C.

Class A (or Class 1) is considered the best fire rating with an FSI of 0 to 25. Buildings such as hospitals often require Class A ratings for their building materials as a fire safety measure. Class B (or Class 2) materials have an FSI between 26 and 75; the FSI for Class C (or Class 3) materials ranges from 76 to 200.

null

What are the 5 fire resistance ratings?

While fire ratings are specific to certain materials in a building, the NFPA's fire resistance ratings assess a building's components and give it a collective rating based on how long it can maintain its structural integrity during a fire. These are the five types according to the NFPA 220:

  • Type 1: Multistory buildings over 75 feet tall that are designed to resist high temperatures and prioritize evacuation from a fire through stairwells
  • Type 2: Newer commercial structures made of non-combustible materials, such as schools or malls
  • Type 3: Brick-and-joist structures, like homes, that are composed of combustible materials
  • Type 4: Buildings where the majority of the structural composition is combustible, but certain elements are non- or limited-combustible
  • Type 5: Buildings with a combustible frame and other structural elements
 

Depending on a building's designated type, certain elements can help boost the non-combustibility of the structure. Applying a fire-resistant coating to flammable surfaces is a more affordable option that can help achieve excellent resistance without replacing structural elements.

For a more costly solution that offers additional benefits, elements of a building can be replaced with better materials such as:

  • Flame-treated natural products
  • Fire-resistant glass for windows
  • Stucco, brick, or concrete
  • Components made with gypsum
null

Whether your building is considered a high-risk Type 5 or a highly non-combustible Type 1 or Type 2, FSS Technologies can help you assess your company's fire hazards and develop a fire safety system that fits your unique needs. With decades of experience, our FSS service technicians can ensure your building meets commercial code requirements and is equipped with the proper fire prevention, protection, and suppression systems. From installations to inspections and everything in between, FSS Technologies has your business covered. Contact us today to learn how we can help you bolster your fire safety.